S allius/issue281 (#282)
* accept DCU serial number starting with '410' * determine sensor-list by serial number * adapt unit test for DCU support * send first batterie measurements to home assistant * add test case for sensor-list==3036 * add more registers for batteries * improve error logging (Monitoring SN) * update the add-on repro only for one stage * add configuration for energie storages * add License and Readme file to the add-on * addon: add date and time to dev and debug docker container tag * disable duplicate code check for config.py * cleanup unit test, remove trailing whitespaces * update changelog * fix example config for batteries * cleanup config.jinja template * fix comments * improve help texts
This commit is contained in:
@@ -78,7 +78,8 @@ class Config():
|
||||
}
|
||||
},
|
||||
'inverters': {
|
||||
'allow_all': Use(bool), And(Use(str), lambda s: len(s) == 16): {
|
||||
'allow_all': Use(bool),
|
||||
And(Use(str), lambda s: len(s) == 16): {
|
||||
Optional('monitor_sn', default=0): Use(int),
|
||||
Optional('node_id', default=""): And(Use(str),
|
||||
Use(lambda s: s + '/'
|
||||
@@ -93,7 +94,7 @@ class Config():
|
||||
},
|
||||
Optional('modbus_polling', default=True): Use(bool),
|
||||
Optional('suggested_area', default=""): Use(str),
|
||||
Optional('sensor_list', default=0x2b0): Use(int),
|
||||
Optional('sensor_list', default=0): Use(int),
|
||||
Optional('pv1'): {
|
||||
Optional('type'): Use(str),
|
||||
Optional('manufacturer'): Use(str),
|
||||
@@ -119,6 +120,33 @@ class Config():
|
||||
Optional('manufacturer'): Use(str),
|
||||
}
|
||||
}
|
||||
},
|
||||
'batteries': {
|
||||
And(Use(str), lambda s: len(s) == 16): {
|
||||
Optional('monitor_sn', default=0): Use(int),
|
||||
Optional('node_id', default=""): And(Use(str),
|
||||
Use(lambda s: s + '/'
|
||||
if len(s) > 0
|
||||
and s[-1] != '/'
|
||||
else s)),
|
||||
Optional('client_mode'): {
|
||||
'host': Use(str),
|
||||
Optional('port', default=8899):
|
||||
And(Use(int), lambda n: 1024 <= n <= 65535),
|
||||
Optional('forward', default=False): Use(bool),
|
||||
},
|
||||
Optional('modbus_polling', default=True): Use(bool),
|
||||
Optional('suggested_area', default=""): Use(str),
|
||||
Optional('sensor_list', default=0): Use(int),
|
||||
Optional('pv1'): {
|
||||
Optional('type'): Use(str),
|
||||
Optional('manufacturer'): Use(str),
|
||||
},
|
||||
Optional('pv2'): {
|
||||
Optional('type'): Use(str),
|
||||
Optional('manufacturer'): Use(str),
|
||||
}
|
||||
}
|
||||
}
|
||||
}, ignore_extra_keys=True
|
||||
)
|
||||
@@ -178,7 +206,7 @@ here. The default config reader is handled in the Config.init method'''
|
||||
rd_config = reader.get_config()
|
||||
config = cls.act_config.copy()
|
||||
for key in ['tsun', 'solarman', 'mqtt', 'ha', 'inverters',
|
||||
'gen3plus']:
|
||||
'gen3plus', 'batteries']:
|
||||
if key in rd_config:
|
||||
config[key] = config[key] | rd_config[key]
|
||||
|
||||
|
||||
@@ -31,7 +31,8 @@ class ConfigReadJson(ConfigIfc):
|
||||
def convert_to_obj(self, data):
|
||||
conf = {}
|
||||
for key, val in data.items():
|
||||
if key == 'inverters' and isinstance(val, list):
|
||||
if (key == 'inverters' or key == 'batteries') and \
|
||||
isinstance(val, list):
|
||||
self.convert_inv_arr(conf, key, val)
|
||||
else:
|
||||
self._extend_key(conf, key, val)
|
||||
|
||||
@@ -113,7 +113,7 @@ inverters.allow_all = false # only allow known inverters
|
||||
##
|
||||
## For each GEN3 inverter, the serial number of the inverter must be mapped to an MQTT
|
||||
## definition. To do this, the corresponding configuration block is started with
|
||||
## `[Inverter.“<16-digit serial number>”]` so that all subsequent parameters are assigned
|
||||
## `[inverters.“<16-digit serial number>”]` so that all subsequent parameters are assigned
|
||||
## to this inverter. Further inverter-specific parameters (e.g. polling mode) can be set
|
||||
## in the configuration block
|
||||
##
|
||||
@@ -132,7 +132,7 @@ pv2 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module de
|
||||
##
|
||||
## For each GEN3PLUS inverter, the serial number of the inverter must be mapped to an MQTT
|
||||
## definition. To do this, the corresponding configuration block is started with
|
||||
## `[Inverter.“<16-digit serial number>”]` so that all subsequent parameters are assigned
|
||||
## `[inverters.“<16-digit serial number>”]` so that all subsequent parameters are assigned
|
||||
## to this inverter. Further inverter-specific parameters (e.g. polling mode, client mode)
|
||||
## can be set in the configuration block
|
||||
##
|
||||
@@ -157,6 +157,33 @@ pv3 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module de
|
||||
pv4 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
|
||||
##########################################################################################
|
||||
##
|
||||
## For each GEN3PLUS enrgy storage system, the serial number must be mapped to an MQTT
|
||||
## definition. To do this, the corresponding configuration block is started with
|
||||
## `[batteries.“<16-digit serial number>”]` so that all subsequent parameters are assigned
|
||||
## to this energy storage system. Further device-specific parameters (e.g. polling mode,
|
||||
## client mode) can be set in the configuration block
|
||||
##
|
||||
## The serial numbers of all GEN3PLUS energy storage systems/batteries start with `410`!
|
||||
## Each GEN3PLUS device is supplied with a “Monitoring SN:”. This can be found on a
|
||||
## sticker enclosed with the inverter.
|
||||
##
|
||||
|
||||
[batteries."4100000000000001"]
|
||||
monitor_sn = 3000000000 # The GEN3PLUS "Monitoring SN:"
|
||||
node_id = '' # MQTT replacement for devices serial number
|
||||
suggested_area = '' # suggested installation place for home-assistant
|
||||
modbus_polling = true # Enable optional MODBUS polling
|
||||
|
||||
# if your inverter supports SSL connections you must use the client_mode. Pls, uncomment
|
||||
# the next line and configure the fixed IP of your inverter
|
||||
#client_mode = {host = '192.168.0.1', port = 8899, forward = true}
|
||||
|
||||
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
|
||||
##########################################################################################
|
||||
###
|
||||
### If the proxy mode is configured, commands from TSUN can be sent to the inverter via
|
||||
|
||||
Reference in New Issue