fixed CJC calibration rule
Did not calibrate if *handle temp* was higher than *tip temp*.
This commit is contained in:
@@ -98,7 +98,7 @@ void performCJCC() {
|
||||
// Calibrate Cold Junction Compensation directly at boot, before internal components get warm.
|
||||
OLED::refresh();
|
||||
osDelay(50);
|
||||
if (!isTipDisconnected() && (TipThermoModel::getTipInC() - getHandleTemperature(0) / 10) < 10) {
|
||||
if (!isTipDisconnected() && abs( int(TipThermoModel::getTipInC() - getHandleTemperature(0) / 10)) < 10) {
|
||||
uint16_t setoffset = 0;
|
||||
// If the thermo-couple at the end of the tip, and the handle are at
|
||||
// equilibrium, then the output should be zero, as there is no temperature
|
||||
@@ -1231,4 +1231,4 @@ void startGUITask(void const *argument) {
|
||||
GUIDelay();
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue