1
0
forked from me/IronOS

Updated documents, fixed English Translation (#1400)

* Update translations_def.js

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Update DebugMenu.md

* Update DebugMenu.md

* Update Development.md

* Update Flashing.md

* Update GettingStarted.md

* Update GettingStarted.md

* Update GettingStarted.md

* Update HallSensor.md

* Update HallSensor.md

* Update HallSensor.md

* Update HallSensor.md

* Update HallSensor.md

* Update HallSensor.md

* Update HardwareIssues.md

* Update HardwareIssues.md

* Update HardwareIssues.md

* Update HardwareIssues.md

* Update HardwareIssues.md

* Update Logo.md

* Update Menu.md

* Update Menu.md

* Update Menu.md

* Update Menu.md

* Update Menu.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Settings.md

* Update Settings.md

* Update Settings.md

* Update translation_EN.json

* Update Settings.md

* Update Settings.md

* Update Settings.md

* Update Settings.md

* Update Settings.md

* Update DebugMenu.md

* Update DebugMenu.md

* Update README.md

* Update translation_FR.json

* Update README.md

* Update Power.md

* Update Troubleshooting.md

* Update Troubleshooting.md

* Update Troubleshooting.md

* Update HardwareIssues.md

* Update DebugMenu.md

* Update DebugMenu.md

* Update Power.md

* Update Power.md

* Update Power.md

* Update Menu.md

* Update Power.md

* Update Documentation/Settings.md

Co-authored-by: discip <53649486+discip@users.noreply.github.com>

* Update Translations/translation_EN.json

Co-authored-by: discip <53649486+discip@users.noreply.github.com>

* Update translation_EN.json

* Update Documentation/Settings.md

Co-authored-by: discip <53649486+discip@users.noreply.github.com>

* Update translation_EN.json

* Update Documentation/Settings.md

Co-authored-by: discip <53649486+discip@users.noreply.github.com>

* Update Settings.md

* Update translation_EN.json

* Update Documentation/Settings.md

Co-authored-by: discip <53649486+discip@users.noreply.github.com>

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Update translation_EN.json

* Add files via upload

* Update translation_EN.json

* Update Settings.md

* Add files via upload

* Update Settings.md

* Update Settings.md

* Update Settings.md

* Add files via upload

* Delete translation_EN.json

* Add files via upload

* Update Power.md

* Update Power.md

* Add files via upload

* Update Settings.md

* Add files via upload

* handle font with no symbols to contribute

* Format

* Generate settings.md menu dock

Co-authored-by: discip <53649486+discip@users.noreply.github.com>
Co-authored-by: Ben V. Brown <Ralim@Ralimtek.com>
This commit is contained in:
River B
2022-09-01 04:14:39 -07:00
committed by GitHub
parent fbddbda940
commit 904428ee19
15 changed files with 483 additions and 430 deletions

View File

@@ -37,14 +37,17 @@ To calibrate your iron:
6. Use the front and back buttons to adjust the displayed voltage to minimize the error to your original measurement
7. Press both buttons at the same time to Save and Exit to the menu
### Calibrating tip offset (Set tip model)
This is normally not needed unless you have an issue with your temperature or your tips are wearing out prematurely. Changing tip lengths does not necessarily mean a calibration is needed. If the method below is not followed, the iron could be worse than before calibration, repeat the method.
Some tips have an offset on their readings which causes issues, i.e., the actual temperature of the tip is much higher than displayed. To calibrate this out, perform the following steps:
### Calibrate Tip CJC
This performs a Tip Cold Junction Calibration (CJC) ([see Temperature for details](/Documentation/Temperature.md)). This is normally not needed unless you have an issue with tip temperature or your tips are wearing out prematurely. Changing tip lengths does not necessarily mean a calibration is needed. Check first that your tips are not defective, and measured resistance is close to specifications (Pinecil/TS100 short tips 6.2 Ω, long tips 8 Ω, TS80(P) ~4.5 Ω).
1. Connect power to your iron
What this is for: some tips have an offset on their readings which causes issues, i.e., the actual temperature of the tip is much higher than displayed. To calibrate this out, perform the following steps.
Caution: if the method below is not followed, the iron could be worse than before calibration. If you need to repeat the method, first unplug and let the handle/PCB cool down to room temperature.
1. Connect power to your iron (tip should be installed).
2. **Critical: make sure the tip & handle is at room temperature** (wait a good while after using the iron before calibration)
3. Using (`-/B`) scroll down to Advanced settings > press (`+/A`) to select > then (`-/B`) to scroll to Calibrate temperature? > press (`+/A`)
4. Important warning message is shown: *Please ensure the tip is at room temperature before proceeding!*
4. Important warning message is shown: *Confirm the tip & device are at room temperature before starting!*
5. Press the (`+/A`) button to confirm (tip/handle are at ambient temperature).
6. Display shows **`....`** for a short time as the unit measures and compares the tip and handle temperatures.
7. The display then goes back to *TMP CAL* and displays your *Offset number*. You generally don't need this offset unless debugging issues.