@@ -35,7 +35,7 @@ This may change during power up as the sources are negotiated in turn.
|
||||
- **DC** input (dumb)
|
||||
- **QC** input (We used QC2/3 negotiation for current supply)
|
||||
- **PD W. VBus** input (PD subsystem is used to negotiate for current supply); and VBus is connected to your input power source
|
||||
- **PD No VBus** input (PD subsystem is used to negotiate for current supply); and VBus is **NOT** connected to your input power source. If it is Not required or possible to do a special mod of your PCB (i.e. late model V1, some early Green PCB models) then [PD No VBus] displays on-screen ([see details and PD Debug section below](/Documentation/DebugMenu.md#pd-debug-menu)).
|
||||
- **PD No VBus** input (PD subsystem is used to negotiate for current supply); and VBus is **NOT** connected to your input power source. If it is Not required or possible to do a special mod of your PCB (i.e. late model V1, some early Green PCB models) then [PD No VBus] displays on-screen ([see details and PD Debug section below](https://ralim.github.io/IronOS/DebugMenu/#pd-debug-menu)).
|
||||
|
||||
### Vin
|
||||
|
||||
@@ -50,7 +50,7 @@ This can be used with RTip for assessing temperature processing performance.
|
||||
|
||||
This is the handle temperature or more accurately the reading of the Cold Junction Compensation (CJC) temperature sensor. This is expressed in °C. Range of 20-40 °C is normal depending on how hot/cold the room is and how long power has been plugged in which warms the PCB further.
|
||||
This is used for CJC of the tip temperature.
|
||||
> If CHan is extremely high, this indicates the temperature sensor isn't reading correctly ([see Troubleshooting](/Documentation/Troubleshooting.md))
|
||||
> If CHan is extremely high, this indicates the temperature sensor isn't reading correctly ([see Troubleshooting](https://ralim.github.io/IronOS/Troubleshooting/))
|
||||
|
||||
|
||||
### Max C
|
||||
@@ -95,7 +95,7 @@ This indicates the high-water mark for the stack for the PID thread. The smaller
|
||||
### Hall
|
||||
|
||||
This appears if your device is capable of having a hall effect sensor installed (Pinecil).
|
||||
This shows the current magnetic field strength reading from the sensor. It is used to check if the sensor is operational, and for diagnostics and optimal placement of magnets on a stand (higher number is better/stronger). [See Hall Sensor for details](/Documentation/HallSensor.md).
|
||||