* Fix units of measurement * Update HallSensor.md * Update DebugMenu.md * Update Troubleshooting.md * Update Temperature.md * Update Temperature.md * Update Power.md * Update Temperature.md * Update Temperature.md * Update DebugMenu.md * Update DebugMenu.md * Update Temperature.md * Update README.md * Update DebugMenu.md * Update Flashing.md * Update Menu.md Co-authored-by: Ben V. Brown <5425387+Ralim@users.noreply.github.com>
This commit is contained in:
@@ -17,8 +17,8 @@ If you can open up your iron, give it a good look at all the connection points,
|
||||
|
||||
If you are finding the tip is reading high; the first fields to check in the Debug menu are `RTip` and `CHan`.
|
||||
|
||||
- `RTip` is the raw tip reading in uV; at cool this should be around 700-1000 for Larger tips and ~1500 for smaller tips (TS80's)
|
||||
- `CHan` is the temperature of the temperature sensor on the PCB in degrees C \* 10. So 29C ambient should read as 290
|
||||
- `RTip` is the raw tip reading in μV; at cool this should be around 700-1000 for Larger tips and ~1500 for smaller tips (TS80's)
|
||||
- `CHan` is the temperature of the temperature sensor on the PCB in degrees Celsius \* 10. So 29 °C ambient should read as 290
|
||||
|
||||
### RTip is out of spec
|
||||
|
||||
|
||||