Files
IronOS/workspace/ts100/src/Settings.c
Ben V. Brown d536fb33de V1.11 - Adding a Boost mode
Allows users to enable a boost mode.
This allows you to hold down the button near the tip while soldering to
temporarily boost the soldering temperature.
Closes #10
2017-07-08 23:16:02 +10:00

62 lines
2.3 KiB
C

/*
* Settings.c
*
* Created on: 29 Sep 2016
* Author: Ralim
*
* This file holds the users settings and saves / restores them to the devices flash
*/
#include "Settings.h"
#define FLASH_ADDR (0x8000000|48896)/*Flash start OR'ed with the maximum amount of flash - 256 bytes*/
void saveSettings() {
//First we erase the flash
FLASH_Unlock(); //unlock flash writing
FLASH_ClearFlag(FLASH_FLAG_EOP | FLASH_FLAG_PGERR | FLASH_FLAG_WRPRTERR);
while (FLASH_ErasePage(FLASH_ADDR) != FLASH_COMPLETE)
; //wait for it
//erased the chunk
//now we program it
uint16_t *data = (uint16_t*) &systemSettings;
for (uint8_t i = 0; i < (sizeof(systemSettings) / 2); i++) {
FLASH_ProgramHalfWord(FLASH_ADDR + (i * 2), data[i]);
}
}
void restoreSettings() {
//We read the flash
uint16_t *data = (uint16_t*) &systemSettings;
for (uint8_t i = 0; i < (sizeof(systemSettings) / 2); i++) {
data[i] = *(uint16_t *) (FLASH_ADDR + (i * 2));
}
//if the version is correct were done
//if not we reset and save
if (systemSettings.version != SETTINGSVERSION) {
//probably not setup
resetSettings();
saveSettings();
}
}
void resetSettings() {
systemSettings.SleepTemp = 1500; //Temperature the iron sleeps at - default 150.0 C
systemSettings.SleepTime = 1; //How many minutes we wait until going to sleep - default 1 min
systemSettings.SolderingTemp = 3200; //Default soldering temp is 320.0 C
systemSettings.movementEnabled = 1; //we use movement detection by default
systemSettings.cutoutVoltage = 10; //10V is the minium cutout voltage as the unit V measurement is unstable below 9.5V
systemSettings.version = SETTINGSVERSION; //Store the version number to allow for easier upgrades
systemSettings.displayTempInF =0; //default to C
systemSettings.flipDisplay=0; //Default to right handed mode
systemSettings.sensitivity=0x00; //Default high sensitivity
systemSettings.tempCalibration=239; //Default to their calibration value
systemSettings.voltageDiv=144; //Default divider from schematic
systemSettings.ShutdownTime=30; //How many minutes until the unit turns itself off
systemSettings.displayUpdateSpeed=1; //How fast the LCD updates
systemSettings.temperatureRounding=0; //How the temperature is rounded off
systemSettings.boostModeEnabled=0; //Default to safe, with no boost mode
systemSettings.BoostTemp=4000; //default to 400C
}