Fomatting and adjust setpoint

This commit is contained in:
Ben V. Brown
2024-12-07 13:11:12 +11:00
committed by Ben V. Brown
parent 6cc8b8184e
commit d313f62101
6 changed files with 11 additions and 11 deletions

View File

@@ -103,8 +103,8 @@
#define DETAILED_IDLE 0 // 0: Disable 1: Enable - Default 0
// Due to large thermal mass of the PCB being heated we need to pull this back a bit
#define THERMAL_RUNAWAY_TIME_SEC 45
#define THERMAL_RUNAWAY_TEMP_C 3
#define THERMAL_RUNAWAY_TIME_SEC 20
#define THERMAL_RUNAWAY_TEMP_C 2
#define CUT_OUT_SETTING 0 // default to no cut-off voltage