# Flashing / Upgrading your iron
## Downloading source file
In the development of this firmware, there are three _types_ of firmware released.
These are the "Main" stable releases, which generally have high confidence in being bug free.
Release candidates are released slightly more often, and these are generally perfectly fine for everyday use. These are released early to allow for translation checking and for wonderful people to help spot bugs and regressions.
Finally, there are the "mainline" builds, which are built from the main git branch.
These are built on every change and can be found on the Actions tab (see below).
### Main release
Main releases are made to the [releases page](https://github.com/Ralim/IronOS/releases).
Download the zip file that matches your model of soldering iron and extract it.
Select the appropriate file type for your unit, in general Miniware devices need `.hex` and Pinecil needs `.dfu`.
Flash according to details below
### Bleeding edge / latest
For the _latest_ code, you will need to download the zip file from the artifacts page on the build for what you want.
Head to the [Actions](https://github.com/Ralim/IronOS/actions) page and then select the run for the appropriate branch you would like.
In general you probably want `master`.
Once you click on a run, scroll down to the "Artifacts" section and then click on your model to download a zip file.
Then this works the same as a production release (use the correct file).
# MHP30
This is completely safe, but if it goes wrong just put the `.hex` file from the official website ([MHP30](https://www.minidso.com/forum.php?mod=viewthread&tid=4385&extra=page%3D1) onto the unit and you're back to the old firmware. Downloads for the `.hex` files to flash are available on the [releases page.](https://github.com/Ralim/IronOS/releases) The file you want is called MHP30.zip. Inside the zip file (make sure to extract the file before flashing with it) will be a file called `MHP30_{Language-Code}.hex`.
Officially the bootloader on the devices only works under Windows (use the built-in File Explorer, as alternative file managers or copy handlers like Teracopy will fail). However, users have reported that it does work under Mac, and can be made to work under Linux _sometimes_. Details over on the [wiki page](https://github.com/Ralim/IronOS/wiki/Upgrading-Firmware).
1. Hold the button closest to the tip (MHP30 the left button on the back), and plug in the USB to the computer.
2. The unit will appear as a USB drive. (Screen will say `DFU` on it.)
3. Drag the `.hex` file onto the USB drive.
4. The unit will disconnect and reconnect.
5. The filename will have changed to end in _.RDY_ or _.ERR_
6. If it ends with _.RDY_ you're done! Otherwise, something went wrong.
7. If it didn't work the first time, try copying the file again without disconnecting the device, often it will work on the second shot.
8. Disconnect the USB and power up the device. You're good to go.
For the more adventurous out there, you can also load this firmware onto the device using an SWD programmer, for easier installation follow the guide at the end of this document.
On the USB-C port, `USB_D+` is shorted to `SWDIO` and `USB_D-` is shorted to `SWCLK` so debugging works without disassembly (attach while staying in the bootloader). Installing [IronOS-dfu](https://github.com/Ralim/IronOS-dfu) is recommended as it allows reliable flashing of binary files with [dfu-util](http://dfu-util.sourceforge.net/).
Noting that for the MHP30 the stock firmware checks a checksum at the end of the first 8k that has to be valid or else it goes into "demo mode".
## Mac
sgr1ff1n (Shane) commented in [issue 11](https://github.com/Ralim/IronOS/issues/11) that upgrading worked on their Mac as per normal:
> I just wanted to say that I was able to update the firmware on my ts100 from the stock version to 1.08 found in this repository using my Mac. I simply followed the same steps however through Finder. I have a MacBook Pro (13-inch, Mid 2012) running Sierra 10.12.4 (16E195).
## Linux
While in the past there were reports of unreliable upgrades, the consensus in [issue 11](https://github.com/Ralim/IronOS/issues/11) is that things work mostly as expected in Linux.
@awigen has contributed a script [flash_ts100_linux.sh](https://raw.githubusercontent.com/Ralim/IronOS/master/Flashing/flash_ts100_linux.sh) that works on Ubuntu 16.04 as well as other distros.
If you want to do it manually (or if the script does not work for some reason) the general procedure is the same as for Windows, the differences are in the way to mount the unit and copy the firmware.
Remember that after flashing, the firmware filename will have changed to end in `.RDY` or `.ERR` or `.NOT` and only `.RDY` means the flashing was successful!
- The unit has to be mounted as `msdos` type (thanks @balrog-kun for having spotted it). You may disable automount, but unmounting the automounted drive and remounting as `msdos` works fine. You do not need to turn off automounting, but you do need to unmount the device with `umount`.
- It is recommended to use an all-caps filename for the firmware, even if successful flashing were done with lower case names.
- Avoid USB hubs, plug directly in your computer.
- If it fails, try again several times without unplugging. Just let it remount.
Example, to be run as root, once the unit has been plugged in DFU mode and auto-mounted:
```bash
FW=ts100.hex
unset NAME
eval $(lsblk -P -p -d --output NAME,MODEL|grep "DFU[ _]Disk")
[ -z ${NAME+x} ] && exit 1 # Could not find DFU device
umount "$NAME"
mkdir /tmp/mntdfu
mount -t msdos "$NAME" /tmp/mntdfu
cp "$FW" "/tmp/mntdfu/$(basename $FW|tr a-z A-Z)"
sync
umount /tmp/mntdfu
rmdir /tmp/mntdfu
```
Device will reboot and automount will rerun if not disabled.
Check the extension of your firmware, it should be `.RDY` now.
## FAQ
#### The file is showing up with the extension `.ERR`
This can occur during the programming process if any of the checks in the bootloader fail. This is often triggered by anti-virus software or using a non-Windows host OS.
First, try just copying the file a second time.
1. Attach the iron in DFU mode.
2. Copy the `.hex` file to the device.
3. The device disconnects and connects with the `.ERR` file.
4. Copy the same `.hex` file again **⛔ DO NOT TRY AND DELETE THE OLD ONE ⛔**.
5. The device will disconnect and reconnect again.
6. The device _should_ now have the `.RDY` file.
7. You're done.
If this fails and you are on Mac or Linux reading the wiki page about programming can help. There is also a very long issue thread going through all of the different attempts around this too.
If you are on Windows, it's often best to try another computer (friends, work, partners etc.).
#### Device randomly disconnects or does not show up in DFU mode
1. Check if the USB cable you are using has the data pins; test it on another device. There are a surprisingly large number of micro-USB cables that are power _only_.
2. Try other USB ports. Often different USB controllers will interact with the units differently due to design quirks in the Miniware design.
### Alternative bootloader
If you are an advanced user, and you have used `usb-dfu` tools before, or you would like to learn; there is an alternative bootloader for these irons.
This will **NOT** show up as a USB storage drive, but instead show up using a standard DFU protocol device. You can then use dfu tools or GUIs to upgrade the iron using the `.bin` files that are posted to the releases page.
To install this alternative bootloader, follow the instructions [here](https://github.com/Ralim/IronOS-dfu/blob/mainline/docs/Bootloader.md).
Note that this is only recommended for users who know what they are doing. If you don't understand how this works, please don't flash this.

View File

@@ -24,75 +24,7 @@ In general you probably want `master`.
Once you click on a run, scroll down to the "Artifacts" section and then click on your model to download a zip file.
Then this works the same as a production release (use the correct file).
# Miniware devices (TS100, TS80, TS80P & MHP30)
This is completely safe, but if it goes wrong just put the `.hex` file from the official website ([TS100](https://www.minidso.com/forum.php?mod=viewthread&tid=868&extra=page%3D1), [TS80](https://www.minidso.com/forum.php?mod=viewthread&tid=3202&extra=page%3D1), [TS80P](https://www.minidso.com/forum.php?mod=viewthread&tid=4070&extra=page%3D1) & [MHP30](https://www.minidso.com/forum.php?mod=viewthread&tid=4385&extra=page%3D1)) onto the unit and you're back to the old firmware. Downloads for the `.hex` files to flash are available on the [releases page.](https://github.com/Ralim/IronOS/releases) The file you want is called _(MODEL)\_EN.hex_ unless you want the translations, they are (MODEL)\__language short name_.hex. Where (MODEL) is either TS100 or TS80.
Officially the bootloader on the devices only works under Windows (use the built-in File Explorer, as alternative file managers or copy handlers like Teracopy will fail). However, users have reported that it does work under Mac, and can be made to work under Linux _sometimes_. Details over on the [wiki page](https://github.com/Ralim/ts100/wiki/Upgrading-Firmware).
1. Hold the button closest to the tip (MHP30 the left button on the back), and plug in the USB to the computer.
2. The unit will appear as a USB drive. (Screen will say `DFU` on it.)
3. Drag the `.hex` file onto the USB drive.
4. The unit will disconnect and reconnect.
5. The filename will have changed to end in *.RDY* or *.ERR*
6. If it ends with *.RDY* you're done! Otherwise, something went wrong.
7. If it didn't work the first time, try copying the file again without disconnecting the device, often it will work on the second shot.
8. Disconnect the USB and power up the device. You're good to go.
For the more adventurous out there, you can also load this firmware onto the device using an SWD programmer, for easier installation follow the guide at the end of this document.
On the bottom of the MCU riser PCB, there are 4 pads for programming. On v2.51A PCB revision `USB_D+` is shorted to `SWDIO` and `USB_D-` is shorted to `SWCLK` so debugging works without disassembly (attach while staying in the bootloader). Installing [IronOS-dfu](https://github.com/Ralim/IronOS-dfu) is recommended as it allows reliable flashing of binary files with [dfu-util](http://dfu-util.sourceforge.net/).
There is a complete device flash backup included in this repository. (Note this includes the bootloader, so will need an SWD programmer to load onto the unit).
For the TS80 the SWD pins are used for the QC negotiation, so you can actually connect to the SWD power via the USB connector.
## Mac
sgr1ff1n (Shane) commented in [issue 11](https://github.com/Ralim/ts100/issues/11) that upgrading worked on their Mac as per normal:
> I just wanted to say that I was able to update the firmware on my ts100 from the stock version to 1.08 found in this repository using my Mac. I simply followed the same steps however through Finder. I have a MacBook Pro (13-inch, Mid 2012) running Sierra 10.12.4 (16E195).
## Linux
While in the past there were reports of unreliable upgrades, the consensus in [issue 11](https://github.com/Ralim/ts100/issues/11) is that things work mostly as expected in Linux.
@awigen has contributed a script [flash_ts100_linux.sh](https://raw.githubusercontent.com/Ralim/ts100/master/Flashing/flash_ts100_linux.sh) that works on Ubuntu 16.04 as well as other distros.
If you want to do it manually (or if the script does not work for some reason) the general procedure is the same as for Windows, the differences are in the way to mount the unit and copy the firmware.
Remember that after flashing, the firmware filename will have changed to end in `.RDY` or `.ERR` or `.NOT` and only `.RDY` means the flashing was successful!
- The unit has to be mounted as `msdos` type (thanks @balrog-kun for having spotted it). You may disable automount, but unmounting the automounted drive and remounting as `msdos` works fine. You do not need to turn off automounting, but you do need to unmount the device with `umount`.
- It is recommended to use an all-caps filename for the firmware, even if successful flashing were done with lower case names.
- Avoid USB hubs, plug directly in your computer.
- If it fails, try again several times without unplugging. Just let it remount.
Example, to be run as root, once the unit has been plugged in DFU mode and auto-mounted:
```bash
FW=ts100.hex
unset NAME
eval $(lsblk -P -p -d --output NAME,MODEL|grep "DFU[ _]Disk")
[ -z ${NAME+x} ] && exit 1 # Could not find DFU device
umount "$NAME"
mkdir /tmp/mntdfu
mount -t msdos "$NAME" /tmp/mntdfu
cp "$FW" "/tmp/mntdfu/$(basename $FW|tr a-z A-Z)"
sync
umount /tmp/mntdfu
rmdir /tmp/mntdfu
```
Device will reboot and automount will rerun if not disabled.
Check the extension of your firmware, it should be `.RDY` now.
# Pinecil V2 (Pine64)
- The MCU in V2 is Bouffalo BL706 and does *not* use usb-dfu for flashing as the previous MCU did.
- The current firmware (2.18) is very fresh and no upgrade is available/needed.
- When an update is released for V2, then IronOS will also include an update method to follow.
- Background on the [BL706 chipset](https://lupyuen.github.io/articles/bl706)
# Pinecil V1 (Pine64)
# Pinecil V1
- The MCU used in Pinecil supports usb-dfu. Reference [Pinecil Wiki](https://wiki.pine64.org/wiki/Pinecil).
- Recommended Updater: the [Pine64 Updater](https://github.com/pine64/pinecil-firmware-updater/releases), is an easy-to-use GUI app. It is fast and works in several types of OS, i.e. Windows/Mac. It will automatically fetch the newest stable version of IronOS from GitHub.
@@ -110,11 +42,11 @@ Check the extension of your firmware, it should be `.RDY` now.
1. Highly recommend updating `dfu-util` to the newest version before starting.
2. Download and extract the firmware package from GitHub [IronOS Releases](https://github.com/Ralim/IronOS/releases).
4. Enter DFU mode: press and hold (`-`) button at the back of the iron before you connect the USB-C cable.
5. Connect USB to PC, and USB-C to back of Pinecil, keep holding (`-`) button down.
6. Once the USB cable is connected at two ends, wait ~10 seconds more, then release the (`-`) button.
7. The screen will stay **black/off** to indicate the Pinecil is in DFU mode. This is normal.
8. Using `dfu-util` you can flash the firmware using a command line like this:
3. Enter DFU mode: press and hold (`-`) button at the back of the iron before you connect the USB-C cable.
4. Connect USB to PC, and USB-C to back of Pinecil, keep holding (`-`) button down.
5. Once the USB cable is connected at two ends, wait ~10 seconds more, then release the (`-`) button.
6. The screen will stay **black/off** to indicate the Pinecil is in DFU mode. This is normal.
7. Using `dfu-util` you can flash the firmware using a command line like this:
```
dfu-util -D Pinecil_EN.dfu
@@ -123,15 +55,20 @@ dfu-util -D Pinecil_EN.dfu
Choose the file name from the folder with the appropriate 2-letter country code for your chosen language (i.e., EN = English).
### Troubleshooting:
- If you get a message stating that `More than one DFU capable USB device found!` when running the above command you probably have an old version of `dfu-util` installed. Might be worth updating. You can still install on the old version, but you will have to specify which DFU interface to flash to. Running the command `dfu-util -l` will show you if there are several DFU devices detected. Example:
```
Found DFU: [28e9:0189] ver=0100, devnum=48, cfg=1, intf=0, path="1-1", alt=1, name="@Option Bytes /0x1FFFF800/01*016Be", serial="??"
Found DFU: [28e9:0189] ver=0100, devnum=48, cfg=1, intf=0, path="1-1", alt=0, name="@Internal Flash /0x08000000/128*001Kg", serial="??"
```
In this example we see that more than one part of the Pinecil is detected as a DFU interface and we need to specify which one we want to flash to. We want the `Internal Flash` so in this case we can use `alt=0` to identify which interface to target. The command would then look like this:
```
dfu-util -D Pinecil_EN.dfu -a 0
```
- Note: if you use an older release of `dfu-util` and do not see `alt=0, name="@Internal Flash /0x08000000/128*001Kg"` when running `dfu-util -l` you likely will not be able to update without first updating 'dfu-util'.
- If your update is crashing part-way into the update, there is sometimes an issue with older/fussy USB controllers (they can show up/disappear/then show up again)
- Try a direct connection to the USB port, do not use a USB hub, and use shorter cable. If possible, pick a port connected to the main board.
@@ -163,7 +100,6 @@ dfu-util -D Pinecil_EN.dfu -a 0
SUBSYSTEM=="usb", ATTR{idVendor}=="28e9", ATTR{idProduct}=="0189", TEST=="power/control", ATTR{power/control}="on"
```
## Windows
Two Options for Windows
@@ -188,8 +124,8 @@ Two Options for Windows
```
dfu-util -D Pinecil_EN.dfu
```
- If you have errors, see Troubleshooting [above](https://ralim.github.io/IronOS/Flashing/#troubleshooting).
- If you have errors, see Troubleshooting [above](https://ralim.github.io/IronOS/Flashing/#troubleshooting).
### Option 2: use the GUI tool from chip vendor
@@ -220,41 +156,4 @@ dfu-util -D Pinecil_EN.dfu
18. Do not need to press any buttons, a new screen should appear.
19. To confirm upgrade, hold the minus (`-`) button down for a few seconds, it then shows new firmware version v2.xx.x....date
- If you have errors, see Troubleshooting [above](https://ralim.github.io/IronOS/Flashing/#troubleshooting).
## FAQ
#### [Miniware] The file is showing up with the extension `.ERR`
This can occur during the programming process if any of the checks in the bootloader fail. This is often triggered by anti-virus software or using a non-Windows host OS.
First, try just copying the file a second time.
1. Attach the iron in DFU mode.
2. Copy the `.hex` file to the device.
3. The device disconnects and connects with the `.ERR` file.
4. Copy the same `.hex` file again **⛔ DO NOT TRY AND DELETE THE OLD ONE ⛔**.
5. The device will disconnect and reconnect again.
6. The device _should_ now have the `.RDY` file.
7. You're done.
If this fails and you are on Mac or Linux reading the wiki page about programming can help. There is also a very long issue thread going through all of the different attempts around this too.
If you are on Windows, it's often best to try another computer (friends, work, partners etc.).
#### [Miniware] Device randomly disconnects or does not show up in DFU mode
1. Check if the USB cable you are using has the data pins; test it on another device. There are a surprisingly large number of micro-USB cables that are power _only_.
2. Try other USB ports. Often different USB controllers will interact with the units differently due to design quirks in the Miniware design.
### [Miniware] Alternative bootloader
If you are an advanced user, and you have used `usb-dfu` tools before, or you would like to learn; there is an alternative bootloader for these irons.
This will **NOT** show up as a USB storage drive, but instead show up using a standard DFU protocol device. You can then use dfu tools or GUIs to upgrade the iron using the `.bin` files that are posted to the releases page.
To install this alternative bootloader, follow the instructions [here](https://github.com/Ralim/IronOS-dfu/blob/mainline/docs/Bootloader.md).
Note that this is only recommended for users who know what they are doing. If you don't understand how this works, please don't flash this.
- If you have errors, see Troubleshooting [above](https://ralim.github.io/IronOS/Flashing/#troubleshooting).

View File

@@ -0,0 +1,32 @@
# Flashing / Upgrading your iron
## Downloading source file
In the development of this firmware, there are three _types_ of firmware released.
These are the "Main" stable releases, which generally have high confidence in being bug free.
Release candidates are released slightly more often, and these are generally perfectly fine for everyday use. These are released early to allow for translation checking and for wonderful people to help spot bugs and regressions.
Finally, there are the "mainline" builds, which are built from the main git branch.
These are built on every change and can be found on the Actions tab (see below).
### Main release
Main releases are made to the [releases page](https://github.com/Ralim/IronOS/releases).
Download the zip file that matches your model of soldering iron and extract it.
Select the appropriate file type for your unit, in general Miniware devices need `.hex` and Pinecil needs `.dfu`.
Flash according to details below
### Bleeding edge / latest
For the _latest_ code, you will need to download the zip file from the artifacts page on the build for what you want.
Head to the [Actions](https://github.com/Ralim/IronOS/actions) page and then select the run for the appropriate branch you would like.
In general you probably want `master`.
Once you click on a run, scroll down to the "Artifacts" section and then click on your model to download a zip file.
Then this works the same as a production release (use the correct file).
# Pinecil V2
- The MCU in V2 is Bouffalo BL706 and does _not_ use usb-dfu for flashing as the previous MCU did.
- The current firmware (2.18) is very fresh and no upgrade is available/needed.
- When an update is released for V2, then IronOS will also include an update method to follow.
- Background on the [BL706 chipset](https://lupyuen.github.io/articles/bl706)

View File

@@ -0,0 +1,120 @@
# Flashing / Upgrading your iron
## Downloading source file
In the development of this firmware, there are three _types_ of firmware released.
These are the "Main" stable releases, which generally have high confidence in being bug free.
Release candidates are released slightly more often, and these are generally perfectly fine for everyday use. These are released early to allow for translation checking and for wonderful people to help spot bugs and regressions.
Finally, there are the "mainline" builds, which are built from the main git branch.
These are built on every change and can be found on the Actions tab (see below).
### Main release
Main releases are made to the [releases page](https://github.com/Ralim/IronOS/releases).
Download the zip file that matches your model of soldering iron and extract it.
Select the appropriate file type for your unit, in general Miniware devices need `.hex` and Pinecil needs `.dfu`.
Flash according to details below
### Bleeding edge / latest
For the _latest_ code, you will need to download the zip file from the artifacts page on the build for what you want.
Head to the [Actions](https://github.com/Ralim/IronOS/actions) page and then select the run for the appropriate branch you would like.
In general you probably want `master`.
Once you click on a run, scroll down to the "Artifacts" section and then click on your model to download a zip file.
Then this works the same as a production release (use the correct file).
# TS100
This is completely safe, but if it goes wrong just put the `.hex` file from the official website ([TS100](https://www.minidso.com/forum.php?mod=viewthread&tid=868&extra=page%3D1) onto the unit and you're back to the old firmware. Downloads for the `.hex` files to flash are available on the [releases page.](https://github.com/Ralim/IronOS/releases) The file you want is called TS100.zip. Inside the zip file (make sure to extract the file before flashing with it) will be a file called `TS100_{Language-Code}.hex`.
Officially the bootloader on the devices only works under Windows (use the built-in File Explorer, as alternative file managers or copy handlers like Teracopy will fail). However, users have reported that it does work under Mac, and can be made to work under Linux _sometimes_. Details over on the [wiki page](https://github.com/Ralim/IronOS/wiki/Upgrading-Firmware).
1. Hold the button closest to the tip (MHP30 the left button on the back), and plug in the USB to the computer.
2. The unit will appear as a USB drive. (Screen will say `DFU` on it.)
3. Drag the `.hex` file onto the USB drive.
4. The unit will disconnect and reconnect.
5. The filename will have changed to end in _.RDY_ or _.ERR_
6. If it ends with _.RDY_ you're done! Otherwise, something went wrong.
7. If it didn't work the first time, try copying the file again without disconnecting the device, often it will work on the second shot.
8. Disconnect the USB and power up the device. You're good to go.
For the more adventurous out there, you can also load this firmware onto the device using an SWD programmer, for easier installation follow the guide at the end of this document.
On the bottom of the MCU riser PCB, there are 4 pads for programming. On v2.51A PCB revision `USB_D+` is shorted to `SWDIO` and `USB_D-` is shorted to `SWCLK` so debugging works without disassembly (attach while staying in the bootloader). Installing [IronOS-dfu](https://github.com/Ralim/IronOS-dfu) is recommended as it allows reliable flashing of binary files with [dfu-util](http://dfu-util.sourceforge.net/).
On some newer TS100 units, the SWD pins are wired up to the USB pins, on older ones they are not sadly.
## Mac
sgr1ff1n (Shane) commented in [issue 11](https://github.com/Ralim/IronOS/issues/11) that upgrading worked on their Mac as per normal:
> I just wanted to say that I was able to update the firmware on my ts100 from the stock version to 1.08 found in this repository using my Mac. I simply followed the same steps however through Finder. I have a MacBook Pro (13-inch, Mid 2012) running Sierra 10.12.4 (16E195).
## Linux
While in the past there were reports of unreliable upgrades, the consensus in [issue 11](https://github.com/Ralim/IronOS/issues/11) is that things work mostly as expected in Linux.
@awigen has contributed a script [flash_ts100_linux.sh](https://raw.githubusercontent.com/Ralim/IronOS/master/Flashing/flash_ts100_linux.sh) that works on Ubuntu 16.04 as well as other distros.
If you want to do it manually (or if the script does not work for some reason) the general procedure is the same as for Windows, the differences are in the way to mount the unit and copy the firmware.
Remember that after flashing, the firmware filename will have changed to end in `.RDY` or `.ERR` or `.NOT` and only `.RDY` means the flashing was successful!
- The unit has to be mounted as `msdos` type (thanks @balrog-kun for having spotted it). You may disable automount, but unmounting the automounted drive and remounting as `msdos` works fine. You do not need to turn off automounting, but you do need to unmount the device with `umount`.
- It is recommended to use an all-caps filename for the firmware, even if successful flashing were done with lower case names.
- Avoid USB hubs, plug directly in your computer.
- If it fails, try again several times without unplugging. Just let it remount.
Example, to be run as root, once the unit has been plugged in DFU mode and auto-mounted:
```bash
FW=ts100.hex
unset NAME
eval $(lsblk -P -p -d --output NAME,MODEL|grep "DFU[ _]Disk")
[ -z ${NAME+x} ] && exit 1 # Could not find DFU device
umount "$NAME"
mkdir /tmp/mntdfu
mount -t msdos "$NAME" /tmp/mntdfu
cp "$FW" "/tmp/mntdfu/$(basename $FW|tr a-z A-Z)"
sync
umount /tmp/mntdfu
rmdir /tmp/mntdfu
```
Device will reboot and automount will rerun if not disabled.
Check the extension of your firmware, it should be `.RDY` now.
## FAQ
#### The file is showing up with the extension `.ERR`
This can occur during the programming process if any of the checks in the bootloader fail. This is often triggered by anti-virus software or using a non-Windows host OS.
First, try just copying the file a second time.
1. Attach the iron in DFU mode.
2. Copy the `.hex` file to the device.
3. The device disconnects and connects with the `.ERR` file.
4. Copy the same `.hex` file again **⛔ DO NOT TRY AND DELETE THE OLD ONE ⛔**.
5. The device will disconnect and reconnect again.
6. The device _should_ now have the `.RDY` file.
7. You're done.
If this fails and you are on Mac or Linux reading the wiki page about programming can help. There is also a very long issue thread going through all of the different attempts around this too.
If you are on Windows, it's often best to try another computer (friends, work, partners etc.).
#### Device randomly disconnects or does not show up in DFU mode
1. Check if the USB cable you are using has the data pins; test it on another device. There are a surprisingly large number of micro-USB cables that are power _only_.
2. Try other USB ports. Often different USB controllers will interact with the units differently due to design quirks in the Miniware design.
### Alternative bootloader
If you are an advanced user, and you have used `usb-dfu` tools before, or you would like to learn; there is an alternative bootloader for these irons.
This will **NOT** show up as a USB storage drive, but instead show up using a standard DFU protocol device. You can then use dfu tools or GUIs to upgrade the iron using the `.bin` files that are posted to the releases page.
To install this alternative bootloader, follow the instructions [here](https://github.com/Ralim/IronOS-dfu/blob/mainline/docs/Bootloader.md).
Note that this is only recommended for users who know what they are doing. If you don't understand how this works, please don't flash this.

View File

@@ -0,0 +1,118 @@
# Flashing / Upgrading your iron
## Downloading source file
In the development of this firmware, there are three _types_ of firmware released.
These are the "Main" stable releases, which generally have high confidence in being bug free.
Release candidates are released slightly more often, and these are generally perfectly fine for everyday use. These are released early to allow for translation checking and for wonderful people to help spot bugs and regressions.
Finally, there are the "mainline" builds, which are built from the main git branch.
These are built on every change and can be found on the Actions tab (see below).
### Main release
Main releases are made to the [releases page](https://github.com/Ralim/IronOS/releases).
Download the zip file that matches your model of soldering iron and extract it.
Select the appropriate file type for your unit, in general Miniware devices need `.hex` and Pinecil needs `.dfu`.
Flash according to details below
### Bleeding edge / latest
For the _latest_ code, you will need to download the zip file from the artifacts page on the build for what you want.
Head to the [Actions](https://github.com/Ralim/IronOS/actions) page and then select the run for the appropriate branch you would like.
In general you probably want `master`.
Once you click on a run, scroll down to the "Artifacts" section and then click on your model to download a zip file.
Then this works the same as a production release (use the correct file).
# TS80 / TS80P
This is completely safe, but if it goes wrong just put the `.hex` file from the official website ([TS80](https://www.minidso.com/forum.php?mod=viewthread&tid=868&extra=page%3D1)/[TS80P](https://www.minidso.com/forum.php?mod=viewthread&tid=4070&extra=page%3D1) onto the unit and you're back to the old firmware. Downloads for the `.hex` files to flash are available on the [releases page.](https://github.com/Ralim/IronOS/releases) The file you want is called TS80.zip or TS80P.zip. Inside the zip file (make sure to extract the file before flashing with it) will be a file called `TS80_{Language-Code}.hex`/`TS80P_{Language-Code}.hex`.
Officially the bootloader on the devices only works under Windows (use the built-in File Explorer, as alternative file managers or copy handlers like Teracopy will fail). However, users have reported that it does work under Mac, and can be made to work under Linux _sometimes_. Details over on the [wiki page](https://github.com/Ralim/TS80/wiki/Upgrading-Firmware).
1. Hold the button closest to the tip (MHP30 the left button on the back), and plug in the USB to the computer.
2. The unit will appear as a USB drive. (Screen will say `DFU` on it.)
3. Drag the `.hex` file onto the USB drive.
4. The unit will disconnect and reconnect.
5. The filename will have changed to end in _.RDY_ or _.ERR_
6. If it ends with _.RDY_ you're done! Otherwise, something went wrong.
7. If it didn't work the first time, try copying the file again without disconnecting the device, often it will work on the second shot.
8. Disconnect the USB and power up the device. You're good to go.
For the more adventurous out there, you can also load this firmware onto the device using an SWD programmer, for easier installation follow the guide at the end of this document.
On the USB port, `USB_D+` is shorted to `SWDIO` and `USB_D-` is shorted to `SWCLK` so debugging works without disassembly (attach while staying in the bootloader). Installing [IronOS-dfu](https://github.com/Ralim/IronOS-dfu) is recommended as it allows reliable flashing of binary files with [dfu-util](http://dfu-util.sourceforge.net/).
## Mac
sgr1ff1n (Shane) commented in [issue 11](https://github.com/Ralim/IronOS/issues/11) that upgrading worked on their Mac as per normal:
> I just wanted to say that I was able to update the firmware on my TS100 from the stock version to 1.08 found in this repository using my Mac. I simply followed the same steps however through Finder. I have a MacBook Pro (13-inch, Mid 2012) running Sierra 10.12.4 (16E195).
## Linux
While in the past there were reports of unreliable upgrades, the consensus in [issue 11](https://github.com/Ralim/IronOS/issues/11) is that things work mostly as expected in Linux.
@awigen has contributed a script [flash_TS100_linux.sh](https://raw.githubusercontent.com/Ralim/IronOS/master/Flashing/flash_TS100_linux.sh) that works on Ubuntu 16.04 as well as other distros.
If you want to do it manually (or if the script does not work for some reason) the general procedure is the same as for Windows, the differences are in the way to mount the unit and copy the firmware.
Remember that after flashing, the firmware filename will have changed to end in `.RDY` or `.ERR` or `.NOT` and only `.RDY` means the flashing was successful!
- The unit has to be mounted as `msdos` type (thanks @balrog-kun for having spotted it). You may disable automount, but unmounting the automounted drive and remounting as `msdos` works fine. You do not need to turn off automounting, but you do need to unmount the device with `umount`.
- It is recommended to use an all-caps filename for the firmware, even if successful flashing were done with lower case names.
- Avoid USB hubs, plug directly in your computer.
- If it fails, try again several times without unplugging. Just let it remount.
Example, to be run as root, once the unit has been plugged in DFU mode and auto-mounted:
```bash
FW=TS80.hex
unset NAME
eval $(lsblk -P -p -d --output NAME,MODEL|grep "DFU[ _]Disk")
[ -z ${NAME+x} ] && exit 1 # Could not find DFU device
umount "$NAME"
mkdir /tmp/mntdfu
mount -t msdos "$NAME" /tmp/mntdfu
cp "$FW" "/tmp/mntdfu/$(basename $FW|tr a-z A-Z)"
sync
umount /tmp/mntdfu
rmdir /tmp/mntdfu
```
Device will reboot and automount will rerun if not disabled.
Check the extension of your firmware, it should be `.RDY` now.
## FAQ
#### The file is showing up with the extension `.ERR`
This can occur during the programming process if any of the checks in the bootloader fail. This is often triggered by anti-virus software or using a non-Windows host OS.
First, try just copying the file a second time.
1. Attach the iron in DFU mode.
2. Copy the `.hex` file to the device.
3. The device disconnects and connects with the `.ERR` file.
4. Copy the same `.hex` file again **⛔ DO NOT TRY AND DELETE THE OLD ONE ⛔**.
5. The device will disconnect and reconnect again.
6. The device _should_ now have the `.RDY` file.
7. You're done.
If this fails and you are on Mac or Linux reading the wiki page about programming can help. There is also a very long issue thread going through all of the different attempts around this too.
If you are on Windows, it's often best to try another computer (friends, work, partners etc.).
#### Device randomly disconnects or does not show up in DFU mode
1. Check if the USB cable you are using has the data pins; test it on another device. There are a surprisingly large number of micro-USB cables that are power _only_.
2. Try other USB ports. Often different USB controllers will interact with the units differently due to design quirks in the Miniware design.
### Alternative bootloader
If you are an advanced user, and you have used `usb-dfu` tools before, or you would like to learn; there is an alternative bootloader for these irons.
This will **NOT** show up as a USB storage drive, but instead show up using a standard DFU protocol device. You can then use dfu tools or GUIs to upgrade the iron using the `.bin` files that are posted to the releases page.
To install this alternative bootloader, follow the instructions [here](https://github.com/Ralim/IronOS-dfu/blob/mainline/docs/Bootloader.md).
Note that this is only recommended for users who know what they are doing. If you don't understand how this works, please don't flash this.

View File

@@ -8,7 +8,7 @@ Simply moving the iron or pressing any button will wake it back up into solderin
### Optional Hall Effect Feature (Pinecil only):
Inside the [Sleep Menu](https://ralim.github.io/IronOS/Settings/#setting-sleep-temp) is an additional type of sleep setting. Pinecil has an unpopulated footprint (**U14**) for a hall effect sensor, Silicon Labs **Si7210-B-00-IV**. After installing the hall effect sensor (HES), it is possible to auto-trigger Pinecil to enter sleep mode when it enters the stand, and *Zzzz* will appear (or text in detailed mode). This could be a fun enhancement for any Pinecil and adds a feature typically only found in more expensive high-end irons. The HES is available at many electronic stores for ~$2-$6.
Inside the [Sleep Menu](https://ralim.github.io/IronOS/Settings/#setting-sleep-temp) is an additional type of sleep setting. Pinecil has an unpopulated footprint (**U14**) for a hall effect sensor, Silicon Labs **Si7210-B-00-IV**. After installing the hall effect sensor (HES), it is possible to auto-trigger Pinecil to enter sleep mode when it enters the stand, and _Zzzz_ will appear (or text in detailed mode). This could be a fun enhancement for any Pinecil and adds a feature typically only found in more expensive high-end irons. The HES is available at many electronic stores for ~$2-$6.
After installing the HES on the PCB, place a magnet on the stand close enough to the sensor to activate one of ten user selectable settings.
@@ -19,6 +19,5 @@ After installing the HES on the PCB, place a magnet on the stand close enough to
- [See debug menu for how to display the _Hall_ number](https://ralim.github.io/IronOS/DebugMenu/)
- Note that the sensor is physically located near the copper contacts for the tip at the front of the handle. [Reference Schematics U14](https://files.pine64.org/doc/Pinecil/Pinecil_schematic_v1.0a_20201120.pdf).
- Neodymium magnets are recommended. If using small magnets, 2-3 may be required, but too many could also be detrimental.
- Positioning/type/quantity of magnets is important for best results. Sometimes too many magnets breaks the effect by distorting the magnetic field **[as seen in this demo video](https://www.youtube.com/shorts/afkqKwCX00I)**. The video shows magnets at the top of the stand, and the pinecil goes correctly into Zzzz with *only* those magnets. When more magnets are added at the side, the Pinecil did not go to sleep, which is contrary to the goal. See the PDF below for details on magnetic fields with SI7210-B.
- Positioning/type/quantity of magnets is important for best results. Sometimes too many magnets breaks the effect by distorting the magnetic field **[as seen in this demo video](https://www.youtube.com/shorts/afkqKwCX00I)**. The video shows magnets at the top of the stand, and the pinecil goes correctly into Zzzz with _only_ those magnets. When more magnets are added at the side, the Pinecil did not go to sleep, which is contrary to the goal. See the PDF below for details on magnetic fields with SI7210-B.
- Orientation of North and South faces of magnets is important to increase reaction of the hall sensor [see data sheet SI7210-B-00-IV](https://www.silabs.com/documents/public/application-notes/an1018-si72xx-sensors.pdf).

View File

@@ -6,7 +6,12 @@ docs_dir: Documentation
nav:
- Home: index.md
- Getting Started: GettingStarted.md
- Flashing the firmware: Flashing.md
- Flashing the firmware:
- MHP30:Flashing/MP30.md
- Pinecil V1:Flashing/Pinecil V1.md
- Pinecil V2:Flashing/Pinecil V2.md
- TS80(P): Flashing/TS80(P).md
- TS100:Flashing/TS100.md
- Operation:
- Main Menu: Menu.md
- Settings: Settings.md
@@ -23,5 +28,4 @@ nav:
- Translations: Translation.md
- Development: Development.md
theme: readthedocs